Residential electrical service - Phoenix, Arizona
Wiring Smoke and CO Detectors in Phoenix, AZ (2026 Guide)
How hardwired smoke and carbon monoxide alarms work, what Phoenix's 2025 code rules and 10-year limit require, and where each alarm belongs.

Quick answer
In Phoenix, smoke alarms and carbon monoxide alarms must take their primary power from the building wiring under the City's amendments to the 2024 International Residential Code, in force since August 1, 2025. Battery-only alarms remain allowed in an existing home only when an alteration or repair leaves wall and ceiling finishes in place and no attic, crawl space or basement offers access for wiring. A City ordinance limits any smoke alarm to 10 years from manufacture. Phoenix Fire recommends alarms outside each sleeping area, on every level and in each bedroom.
A smoke alarm is a small device with a large job, and in Phoenix the rules about how it is powered changed in 2025. The City's amendments to the 2024 International Residential Code now require smoke alarms and carbon monoxide alarms to take their primary power from the building wiring, and a City ordinance already limited any smoke alarm to 10 years of service. That makes wiring smoke detectors an electrical question as much as a safety one.
This guide explains what a hardwired, interconnected alarm system is, what the Phoenix rules say and where they stop, where the Phoenix Fire Department says alarms belong, how carbon monoxide alarms fit in, what the national fire data shows, and what to check before and after the work.
Key takeaways
- Phoenix's amendment to the 2024 International Residential Code, in force since August 1, 2025, requires smoke alarms to take their primary power from the building wiring.
- Phoenix applies the same building-wiring power rule to carbon monoxide alarms under its amended Section R311.6.
- Battery-only alarms are allowed in an existing Phoenix home only when an alteration or repair leaves wall and ceiling finishes in place and no attic, crawl space or basement gives access for wiring.
- The Phoenix Fire Department says city ordinance G-5898-2014 limits any smoke alarm to 10 years of service from its date of manufacture.
- The Phoenix Fire Department recommends a smoke alarm outside each sleeping area, on every level of the home and, for the most protection, in each bedroom.
- City of Phoenix permit guidance exempts low-power signal circuits from permits only when they are not part of a life-safety system.
What does wiring smoke detectors in a Phoenix home involve?
A hardwired smoke alarm takes its power from a household circuit through cable run to its mounting box, instead of depending only on a battery. The Phoenix Fire Department notes that hardwired alarms usually also carry a backup battery, so they keep working when the power goes out. Hardwired alarms can also be interconnected, so that when one alarm senses smoke, every alarm in the house sounds. A fire that starts in a back bedroom then wakes the people asleep at the other end of the house, not only the people nearest the smoke.
The electrical work has three parts:
- A power source. The alarms are fed from a circuit that starts at a breaker in the panel. If that breaker trips, it is a circuit breaker question as much as an alarm question.
- Cable between locations. Cable runs from one alarm location to the next, carrying power and, on an interconnected system, the signal that makes the alarms sound together.
- A box and connector at each location. Each alarm plugs into a connector held in a box in the ceiling or wall.
Replacing an existing hardwired alarm is the smallest version of the job. Adding hardwired, interconnected alarms to a house that has only battery units is the largest, because cable has to reach every location. In single-story Phoenix homes crews usually reach the bedroom and hallway ceilings from the attic, so the cable route matters more than the number of alarms, and the attic work is scheduled early in the day while the space is still safe to enter.
Smoke alarms and carbon monoxide alarms can be separate devices or combined in one unit. Either way, Phoenix's amended residential code treats their power source the same way, which is the subject of the next section.
What do Phoenix's 2025 code amendments require for smoke and CO alarm power?
The City of Phoenix adopted the 2024 Phoenix Building Construction Codes by City Council action on June 18, 2025, and the City's Building Code page says those codes, which include the 2023 National Electrical Code, took effect on August 1, 2025. As part of that package the City amended the 2024 International Residential Code under Ordinance G-7397.
Two of those amendments set the power source for alarms:
- Smoke alarms, Section R310.6. The amended text reads: "Smoke alarms shall receive their primary power from the building wiring."
- Carbon monoxide alarms, Section R311.6. The amended text reads: "Carbon monoxide alarms shall receive their primary power from the building wiring." The same limited battery exception for alterations and repairs applies.
The City explained why it made the change. Its justification for the R310.6 amendment says, in substance, that the base code language could let full gut remodels and whole-house rewires use battery-only alarms, and that projects of that size should meet the same power requirement as new homes. In other words, Phoenix closed a route that would have let a house be stripped to the studs and rewired while its alarms stayed on batteries.
A third amendment links alarms to window security bars. Phoenix's amended Section R319.4.4, which covers bars, grilles, covers and screens on windows, says that where such devices are installed, "The dwelling shall be equipped with smoke alarms installed in accordance with Section R310." The practical effect is that a homeowner adding window bars also needs smoke alarms that meet R310, including its building-wiring power rule.
Note what these sections cover: how alarms are powered, and when alarms are required alongside security bars. This page found no City document saying that a permit for other work, such as a panel upgrade, automatically requires smoke alarms to be added or upgraded throughout the house. Do not assume it does or does not; ask the contractor and, where it is unclear, the City.
When can a Phoenix home still use battery-only smoke alarms?
Only in a narrow case. Exception 2 to Phoenix's R310.6 allows battery-powered smoke alarms in existing homes where the alteration or repair does not remove interior wall or ceiling finishes. Even then, the exception does not apply "unless there is an attic or crawl space or basement available which could provide access for hardwiring of smoke alarms." Read together, a battery-only alarm is acceptable during an alteration or repair only when both of these are true:
- The work leaves the interior wall and ceiling finishes in place.
- There is no attic, crawl space or basement that could give access for running wiring to the alarms.
That second condition matters in Phoenix. In a single-story house with an attic above the bedrooms and hallway, the attic is exactly the access the City's wording describes, so the battery exception is unlikely to fit. It fits more naturally where there is no practical space above or below the rooms to run cable.
The carbon monoxide amendment, R311.6, carries the same limited battery exception for alterations and repairs, so the same reasoning applies to CO alarms.
Two cautions apply. First, these sections describe what applies when alarms are installed during work on the house; in the text read for this page, they are not an order for every existing home to rewire its alarms today. Second, whether a particular project counts as an alteration that removes finishes, and whether a given attic offers usable access, are judgments for the contractor and the inspector on that job. Where a home already has a mix of hardwired and battery alarms, planning toward the hardwired, interconnected arrangement the code now expects avoids redoing the work when a later remodel opens a ceiling.
How long can a smoke alarm stay in service in Phoenix?
Ten years from its date of manufacture. The Phoenix Fire Department says that under city ordinance G-5898-2014 "a smoke alarm cannot remain in service longer than 10 years from the date of manufacture." The count starts at manufacture, not installation, so an alarm that sat on a shelf for a while before it went up has less service left than its installation date suggests.
The same Phoenix Fire page says that since April 2014, homeowners replacing outdated, missing or damaged smoke alarms must install alarms with 10-year sealed batteries, and that any alarm whose age is unknown should be replaced. An alarm with no readable date, one that has been painted over, or one older than anyone in the house can remember, falls into that last group.
Two practical points follow for a hardwired system:
- Replace by date, not by symptom. An alarm can test and look fine and still be past its 10 years. Crews check the manufacture date on the back of each alarm before anything else, because that date decides the job.
- Replace alarms of the same age together. Alarms installed at the same time reach the 10-year limit together. On an interconnected system, replacement units also have to work with each other and with the existing connectors, which is easier to get right when the set is replaced as a group.
The Phoenix Fire page states the sealed-battery requirement without separately describing hardwired units. When a hardwired alarm is replaced, ask the electrician which replacement meets both the ordinance and the City's building-wiring rule, and check with the Phoenix Fire Department if the answer is not clear. Carbon monoxide alarms follow a different clock: the NFPA sheet hosted by Phoenix Fire says to replace them according to the manufacturer's schedule.
Where does the Phoenix Fire Department say to put smoke alarms?
The Phoenix Fire Department recommends a smoke alarm outside each sleeping area and on every level of the home, and one in each bedroom for the most protection. Hallways longer than 30 feet should have an alarm at each end, and there should be one at the top of each stairwell. In a single-story Phoenix home, that means alarms in the bedrooms and in the hallway outside them, with a second hallway alarm where the hall runs longer than 30 feet.
The same page gives mounting rules that decide exactly where each box goes:
- On a wall, mount the alarm at least 12 inches from the ceiling.
- On a ceiling, mount it at least 18 inches from the dead-air space near walls and corners.
- Keep it more than three feet from fireplaces, wood stoves, drafts, windows, doors and air registers.
- Do not install it in laundry rooms or garages.
- In a kitchen, keep it away from cooking fumes.
On Phoenix jobs, crews often find a hallway ceiling that already carries an air-conditioning register, and the new box is placed to keep the three-foot distance Phoenix Fire sets, even when the old alarm sat closer. When a battery-only house is converted to hardwired alarms, the old locations are not automatically the right ones. The rewiring is the moment to put each alarm where the guidance says it belongs, because moving a box later means opening the ceiling again.
Where should carbon monoxide alarms go in a Phoenix home?
An NFPA carbon monoxide safety sheet hosted on the Phoenix Fire Department site says "CO alarms should be installed in a central location outside each sleeping area and on every level of the home," and that interconnecting all alarms, so all of them sound when one does, gives the best protection. The U.S. Consumer Product Safety Commission gives the same locations, "on every level of the home and outside sleeping areas," says interconnected alarms are preferred, and does not recommend putting CO alarms in kitchens or above fuel-burning appliances. CPSC refers to battery or battery-backup alarms; in Phoenix, the amended R311.6 adds that the primary power comes from the building wiring.
Carbon monoxide comes from burning fuel. CPSC lists malfunctioning furnaces, ranges, water heaters and room heaters among the sources and warns: "Never leave a car running in an attached garage, even with the garage door open." The NFPA sheet adds that no vehicle or fueled engine should be run indoors, "even if garage doors are open," and that fuel-burning heating equipment and chimneys should be inspected by a professional every year before cold weather.
For a Phoenix homeowner, the useful question is which of those sources the house has. A gas water heater, gas furnace or gas range, a fireplace, an attached garage, and a portable generator used during an outage are the usual candidates. A portable generator is a fueled engine and must never be run indoors; permanently installed units are covered on the home generator installation page.
On the scale of the risk, CPSC says that, on average, more than 200 people in the United States die each year from carbon monoxide produced by non-automotive consumer products. That is a national figure. This page found no Phoenix-specific count of carbon monoxide incidents, and no City rule tying CO alarms to particular appliances or to attached garages beyond the power-source amendment, so none is stated here.
How often were smoke alarms working in fatal U.S. home fires?
National data shows how often a working alarm is missing when it matters. The U.S. Fire Administration's report on fatal fires in residential buildings from 2018 to 2020 found that about one-third of those fires had a smoke alarm present and about one-quarter had no smoke alarm at all, and it notes that the no-alarm share is likely an undercount. USFA's national estimates averaged 2,745 residential fire deaths a year over that period. NFPA states that "Smoke alarms cut the risk of dying in a home fire in half."
The chart breaks the reported fatal fires down by what the alarm did.
| Smoke alarm status | Share of 3,683 reported fatal fires |
|---|---|
| Alarm present and operated | 15.8% |
| Alarm present, failed to operate | 6.5% |
| Alarm present, status unknown | 11.2% |
| No alarm present | 24.0% |
| Undetermined | 42.2% |
How we got this table. The figures come from the U.S. Fire Administration report Fatal Fires in Residential Buildings (2018-2020), Topical Fire Report Series Volume 22, Issue 2, published June 2022. They are shares of 3,683 fatal fires in occupied homes reported to the National Fire Incident Reporting System, summed from reported counts, not national estimates. The operated row is our grouping of five operated sub-categories in the report (583 fires). A further 0.2 percent of fires, where the fire was too small to activate the alarm, is omitted, so the rows total 99.7 percent. These are national figures, not Phoenix figures.
Read across the bars, the gap between an alarm being present and an alarm doing its job is plain. In 6.5 percent of the reported fatal fires an alarm was present and failed to operate, and the Phoenix Fire Department says missing or dead batteries are the main reason alarms fail to sound in a fire. A hardwired alarm addresses that failure directly, because the house wiring, not the battery, is its primary power, and the battery is only the backup. The large undetermined share is a reminder that fire investigations often cannot establish what an alarm did, which is also why USFA cautions that the no-alarm share is likely an undercount.
Does adding or replacing hardwired smoke alarms need a permit in Phoenix?
It can, and the City's guidance makes one point clearly. The City of Phoenix Planning and Development Department's Work Exempt from Permit guidance exempts Class 2 and Class 3 low-power control and signal circuits from permits only "provided they are not part of a life-safety system." Smoke and carbon monoxide alarms are life-safety equipment, so that low-voltage exemption is not a route around a permit for alarm wiring.
Separately, the City's Online Permits guidance says residential permits allow residents and contractors to do minor electrical remodel work, including adding or extending circuits. Running new cable to reach alarm locations, or adding a circuit to feed them, is work of that kind. Swapping one hardwired alarm for another on the same connector is a smaller task; whether a particular replacement needs a permit is a question to settle with the contractor before the work starts, and with the City where it is unclear.
Permitted work is inspected against the codes Phoenix has adopted, which include the 2023 National Electrical Code and the amended residential code described above. The City also offers a residential field consultation permit, which lets a resident meet an inspector on site to ask technical questions or to get advice about work that was done without a permit. That is useful when an older house turns out to have alarm wiring of uncertain origin. A broader look at the house's wiring is covered under home electrical inspections.
When alarm work is part of a bigger project, such as an electrical panel upgrade or a remodel, ask how the alarms are being handled. Because no City document found for this page says that a permit for other work automatically requires alarms throughout the house, the answer depends on the scope of the job and, under R310.6, on whether wall or ceiling finishes come off and whether the attic gives access.
How should hardwired smoke and CO alarms be tested and maintained?
Hardwiring removes the main battery problem, but not the need for care. The Phoenix Fire Department advises checking smoke alarms monthly, vacuuming them monthly and never painting them. The NFPA carbon monoxide sheet says to test CO alarms monthly and replace them according to the manufacturer's schedule.
- Test every alarm, not just the one in the hall. On an interconnected system, pressing test on one alarm should sound all of them; if one stays silent, that unit or its interconnect needs attention.
- Keep the backup battery current. Phoenix Fire notes that hardwired alarms usually include a backup battery for power failures, and that missing or dead batteries are the main reason alarms fail to sound.
- Vacuum them monthly, as Phoenix Fire advises. After a monsoon storm has pushed dust into the house is a sensible time to do it.
- Never paint over an alarm. During a remodel, cover it while painting and uncover it afterwards.
- Read the dates once a year and plan replacement before any smoke alarm reaches 10 years from manufacture.
A hardwired alarm that misbehaves is worth checking at the unit first: its date, its backup battery and its dust. If the problem moves around the house or affects several alarms at once, the circuit or the interconnect is the next place to look, which is ordinary electrical repair work.
What are the common mistakes with smoke and CO detectors in Phoenix homes?
- Assuming a passing test means the alarm can stay. In Phoenix a smoke alarm reaches the end of its permitted service 10 years from its date of manufacture, whatever the test button says.
- Replacing a hardwired alarm with a battery-only unit. It drops the building-wired primary power the City's code expects and breaks the interconnection with the other alarms.
- Remodeling around battery alarms. If wall or ceiling finishes come off, or the attic gives access, Phoenix's R310.6 and R311.6 expect alarms powered from the building wiring.
- Putting an alarm next to an air register or in the garage. Phoenix Fire says to keep alarms more than three feet from registers and out of garages and laundry rooms.
- Mounting a CO alarm in the kitchen or above a gas appliance. CPSC does not recommend either location.
- Treating alarm cable as low-voltage work that needs no permit. The City's permit exemption for low-power circuits does not cover life-safety systems.
Who installs hardwired smoke and CO alarms requested through Your Phoenix Electrician?
Arizona licenses electrical contractors through the Registrar of Contractors. The Arizona Administrative Code describes the R-11 Electrical classification as allowing the licensee to install and repair residential electrical systems, and the circuits and cable that power a home's alarms are part of that system. Ask for the license number and classification before work begins.
Smoke and carbon monoxide alarm wiring requested through Your Phoenix Electrician is performed by Alvey Electric LLC, Arizona Registrar of Contractors license ROC 364723, R-11 Electrical (residential). The work is residential only.
Frequently asked questions
Do smoke detectors have to be hardwired in Phoenix?
In most cases where alarms are installed as part of construction or work on the house, yes. Phoenix's amendment to the 2024 International Residential Code, effective August 1, 2025, says smoke alarms shall receive their primary power from the building wiring. Battery-only alarms remain allowed in an existing home only when an alteration or repair leaves wall and ceiling finishes in place and there is no attic, crawl space or basement giving access for hardwiring.
When can a Phoenix home still use battery-only smoke alarms?
Only when two conditions are both met during an alteration or repair: the work does not remove interior wall or ceiling finishes, and no attic, crawl space or basement is available that could provide access for hardwiring. That is Exception 2 to Phoenix's amended Section R310.6. In a single-story house with an attic above the bedrooms, the second condition is unlikely to be met, so plan on hardwired alarms.
How long can a smoke alarm stay in service in Phoenix?
Ten years from its date of manufacture. The Phoenix Fire Department says city ordinance G-5898-2014 sets that limit, and that since April 2014 homeowners replacing outdated, missing or damaged smoke alarms must install alarms with 10-year sealed batteries. Phoenix Fire also says to replace any alarm whose age is unknown, so check the manufacture date on the back of each alarm.
Where should smoke detectors go in a Phoenix house?
The Phoenix Fire Department recommends a smoke alarm outside each sleeping area and on every level of the home, with one in each bedroom for the most protection. Hallways longer than 30 feet should have one at each end, plus one at the top of each stairwell. Keep alarms more than three feet from air registers, windows, doors and fireplaces, and do not install them in garages or laundry rooms.
Where should a carbon monoxide detector be installed?
An NFPA sheet hosted by the Phoenix Fire Department says CO alarms should go in a central location outside each sleeping area and on every level of the home, and that interconnected alarms give the best protection. CPSC gives the same locations and does not recommend installing CO alarms in kitchens or above fuel-burning appliances. In Phoenix, the amended code requires their primary power to come from the building wiring.
Do I need a carbon monoxide alarm if my home has no gas appliances?
Carbon monoxide comes from burning fuel, so look at everything in or attached to the house that burns it. CPSC lists furnaces, ranges, water heaters and room heaters as sources and warns never to leave a car running in an attached garage, even with the door open. This page found no City of Phoenix rule tying CO alarms to particular appliances or garages, so ask the contractor what applies to your house and your project.
Do I need a permit to hardwire smoke detectors in Phoenix?
It depends on the scope. The City of Phoenix says residential permits cover minor electrical work including adding or extending circuits, which is what running new cable or a new circuit for alarms involves. Its Work Exempt from Permit guidance exempts low-power signal circuits only when they are not part of a life-safety system. Whether a like-for-like alarm replacement needs a permit is a question to settle with the contractor and, if unclear, the City.
How much does it cost to hardwire smoke detectors in Phoenix?
This page does not quote a price, because no public source sets one. The cost depends on whether wiring already reaches the alarm locations, how many alarms the Phoenix Fire placement guidance calls for in your layout, how easily cable can be run through the attic, whether the alarms are interconnected and include carbon monoxide alarms, and whether a permit and inspection are part of the job. Ask for the scope and the price together.
Why does my hardwired smoke detector keep chirping?
Start with the points the Phoenix Fire Department raises: hardwired alarms usually carry a backup battery, and missing or dead batteries are the main reason alarms fail. Check the alarm's manufacture date too, because in Phoenix a smoke alarm cannot stay in service more than 10 years from that date, and vacuum it, since Phoenix Fire advises monthly cleaning. If several alarms misbehave together, have the circuit and interconnect checked.
Can I get free smoke alarms in Phoenix?
Free alarm events have happened in Phoenix. FOX 10 Phoenix reported in March 2018 that Phoenix firefighters and volunteers went door to door checking and installing free smoke alarms, and the American Red Cross held a Sound the Alarm volunteer day in Phoenix on October 15, 2022 with the Phoenix Fire Department and the City. This page found no current City program for requesting a free installation, so check with Phoenix Fire or the Red Cross for anything current.
Should smoke and CO alarms be interconnected?
Interconnection is recommended. The NFPA carbon monoxide sheet hosted by the Phoenix Fire Department says interconnecting all alarms, so all of them sound when one does, gives the best protection, and CPSC says interconnected CO alarms are preferred. In practice, interconnection means an alarm sounding at one end of the house also wakes the people sleeping at the other end.
Who installs smoke and CO alarms requested through Your Phoenix Electrician?
Smoke and carbon monoxide alarm wiring requested through Your Phoenix Electrician is performed by Alvey Electric LLC, Arizona Registrar of Contractors license ROC 364723, R-11 Electrical (residential). The Arizona Administrative Code describes the R-11 Electrical classification as allowing the licensee to install and repair residential electrical systems. The work is residential only.
The short version
Treat smoke and carbon monoxide alarms in Phoenix as part of the house wiring, not as stand-alone gadgets: the City now expects building-wired primary power, and any smoke alarm 10 years past its manufacture date is due out. If walls or ceilings are opening, or the attic gives access, plan for hardwired, interconnected alarms at the locations Phoenix Fire recommends. If nothing is changing, read the dates, test monthly and replace same-age alarms as a set before they expire.
This page is general information about residential electrical work in Phoenix, Arizona. It is not engineering, legal or code advice for a specific property. Permit rules, utility requirements, rebates and adopted codes change; confirm current requirements with the City of Phoenix and your utility before work begins.
References
- City of Phoenix, Amendment to 2024 International Residential Code (Ordinance G-7397, Council action June 18, 2025, effective August 1, 2025): Sections R310.6, R311.6, R319.4.4 https://www.phoenix.gov/content/dam/phoenix/pddsite/documents/codes-ordinances/amendmentcodes/2024-irc.pdf. Read November 25, 2026.
- Phoenix Fire Department, Smoke Alarms Save Lives (ordinance G-5898-2014, placement and maintenance guidance) https://www.phoenix.gov/administration/departments/fire/safety-prevention/fire-safety-information/smoke-alarms-save-lives.html. Read November 25, 2026.
- NFPA, Carbon Monoxide Safety tip sheet (2017), hosted by City of Phoenix Fire Department https://www.phoenix.gov/content/dam/phoenix/firesite/documents/cosafety.pdf. Read November 25, 2026.
- U.S. Consumer Product Safety Commission, Carbon Monoxide Fact Sheet https://www.cpsc.gov/safety-education/safety-guides/carbon-monoxide/carbon-monoxide-fact-sheet. Read November 25, 2026.
- U.S. Fire Administration, Fatal Fires in Residential Buildings (2018-2020), Topical Fire Report Series Vol. 22 Issue 2, June 2022 https://www.usfa.fema.gov/downloads/pdf/statistics/v22i2.pdf. Read November 25, 2026.
- NFPA, Learn More About Smoke Alarms https://www.nfpa.org/education-and-research/home-fire-safety/smoke-alarms. Read November 25, 2026.
- City of Phoenix Planning and Development Department, Work Exempt from Permit, TRT/DOC/00618 (Rev. 07/14) https://www.phoenix.gov/content/dam/phoenix/pddsite/documents/trt/external/dsd_trt_pdf_00618.pdf. Read November 25, 2026.
- City of Phoenix Planning and Development Department, Online Permits, TRT/DOC/00933 (residential permits; field consultation permit) https://www.phoenix.gov/content/dam/phoenix/pddsite/documents/trt/external/dsd_trt_pdf_00933.pdf. Read November 25, 2026.
- City of Phoenix Planning and Development Department, Building Construction Codes (2023 National Electrical Code; effective August 1, 2025) https://www.phoenix.gov/administration/departments/pdd/tools-resources/codes-ordinance/building-code.html. Read November 25, 2026.
- City of Phoenix, 2024 Phoenix Building Construction Code Implementation (adopted June 18, 2025) https://web-prod.phoenix.gov/content/dam/phoenix/pddsite/documents/codes-ordinances/amendmentcodes/2024-building-code-implementation.pdf. Read November 25, 2026.
- Arizona Administrative Code R4-9-103, Residential Contractor License Classifications and Scopes of Work (R-11 Electrical) https://www.law.cornell.edu/regulations/arizona/Ariz-Admin-Code-SS-R4-9-103. Read November 25, 2026.
- FOX 10 Phoenix, Phoenix Fire give out and install new smoke detectors in neighborhood, March 31, 2018 https://www.fox10phoenix.com/news/phoenix-fire-give-out-and-install-new-smoke-detectors-in-neighborhood. Read November 25, 2026.
- American Red Cross Arizona and New Mexico, Sound the Alarm event, October 15, 2022 https://www.redcross.org/local/az-nm/about-us/news-and-events/events/sound-the-alarm-arizona-new-mexico.html. Read November 25, 2026.
Plan your alarm wiring
Request an estimate for hardwired smoke and carbon monoxide alarms in your Phoenix home.
Related pages
- Home electrical inspections in Phoenix
- Electrical repair and troubleshooting in Phoenix
- Circuit breaker repair and replacement in Phoenix
- Electrical panel upgrade in Phoenix
- Home generator installation in Phoenix
- Outlet installation and repair in Phoenix
- Phoenix neighborhoods and villages we serve
- Your Phoenix Electrician home
About this page
Written by the Your Phoenix Electrician editorial team from the sources listed above. Reviewed by Robert "Bob" Lira, licensed Arizona electrical contractor, ROC 338369. Your Phoenix Electrician, 4315 E Thunderbird Rd #120, Phoenix, AZ 85032, phone 602-900-0593, serves homes in the City of Phoenix. Electrical work is performed by Alvey Electric LLC, Arizona Registrar of Contractors license ROC 364723 (residential electrical).